CaManSys Clash Management Suite - Standard

CaManSys Clash Management Suite - Standard

Win32 및 64, 한국어

Matt Klassen Consulting Inc.
Manage Autodesk® Navisworks® Clashes in Autodesk® AutoCAD®.

일반 사용 지침

Create Navisworks Manage model for Clash tests

Define Clash Tests

Run Clash tests

Write clash tests to xml file (as separate tests)

Open AutoCAD Model

Insure Clash Palette is visible

Select Clash in Clash List, resolve Clash and/or update status and comment

Repeat as necessary, open next AutoCAD Model

Review Import changes back into Navisworks Manage

명령

리본/도구막대 아이콘 명령 명령 설명

CMSA_TLCL_XREFAUTOLOAD

Enable / Disable Xref Autoload Switch between loading xrefs when Clash Environment opened, or on demand per clash.

Review

Update/Review Clash Comments, and Statuses (Navisworks)

Configure

Configure Clash Tests for current Project (Navisworks)

CMSA_TLCL_CHECKUPDATE

Check if Add-in updates are available

CMSA_TLCL_SHOW

Show Clash Management Panel (AutoCAD)

CMSA_TLCL_ISOLATION

Enable/Disable Clash Isolation

CMSA_TLCL_REG

Enter/Purchase Registration key.

CMSA_TLCL_HELP

Displays Help File

CMSA_TLCL_LOADCONFIG

Load Configuration File

CMSA_TLCL_RESTOREVIEW

Switch between Navisworks View, and saved AutoCAD View (AutoCAD Only)

CMSA_TLCL_PURGE

Remove Clash data from Model (AutoCAD)

About

CMSA_TLCL_ABOUT (AutoCAD) Display Add-in Information

설치/설치제거

Run the installation file (cmsClashManagement_Standard.exe).

Choose to Install AutoCAD Add-in (if AutoCAD is installed on workstation) and/or NavisWorks Manage Add-in (if Navisworks Manage is installed on workstation)

Uninstall the Addin through Control Panel\All Control Panel Items\Programs and Features->cms Clash Management Suite

추가 정보

Tutorial available at: http://docs.camansol.com/tutorials/cmsACTLClashTutorial/V30/index.htm

Sample file location C:\ProgramData\Autodesk\ApplicationPlugins\cmsClashManagementSuite.bundle\Samples\COS160501.zip

알려진 문제

Not all components in the AutoCAD Model are dimmed correctly when isolating the clash components. To work around this issue, you can change the highlight colors, or turn Isolation off. This will make the clash components easier to see.

Pressing F1 for help on the ribbon buttons in Navisworks Manage does not work as expected (AutoCAD is fine). Either two tabs will be opened in the browser (Clash Management Suite on one, and Naviswork Manage Help on the other) or one tab displaying Navisworks Manage Help. The Help documentation works as expected in the panels. We are trying to figure this out.

문의

회사 이름: Matt Klassen Consulting Inc.
지원 연락처: support@camansol.com

작성자/회사 정보

Matt Klassen Consulting Inc.

지원 정보

Visit http://www.camansol.com/frames/ContactUS.html

Local: 403.457.0710

Toll free: 877.679.4965

Email: support@camansol.com

버전 내역

버전 번호 버전 설명

3.0.0.1

Updated for AutoCAD 2020 products 3.0.0.0 New Features Performance Enhancements Disable Clash Isolation Clash Isolation can now be completely disabled. Load xrefs automatically, or on demand Xrefs can be loaded and unloaded for specific clashes Useability Enhancements Test File Names against model naming convention format Improved support for Imperial models Version 2.0.0.0 Update Licensing Framework New License Status Notification 1.5.0.0 Updated Clash File Management Clash Files are now defined in a column in the Discipline Table. 1.0.0.0 Initial Release

3.0.0.0

New Features Performance Enhancements Disable Clash Isolation Clash Isolation can now be completely disabled. Load xrefs automatically, or on demand Xrefs can be loaded and unloaded for specific clashes Useability Enhancements Test File Names against model naming convention format Improved support for Imperial models Version 2.0.0.0 Update Licensing Framework New License Status Notification 1.5.0.0 Updated Clash File Management Clash Files are now defined in a column in the Discipline Table. 1.0.0.0 Initial Release
맨 위로 이동