BIM SOFT SOLUTIONS ALL TOOLS PACKAGE

BIM SOFT SOLUTIONS ALL TOOLS PACKAGE

Win64, English

BIM SOFT SOLUTIONS
This application contains more than 100 useful tools to facilitate work in Autodesk® Revit®.

General Usage Instructions

After the installation, you can find the tools under 'BIM_SOFT_GENERAL_PACKAGE' , 'BIM_SOFT_PACKAGE(MEP)' , 'BIM_SOFT_(Parameters Package)' , 'BIM_SOFT_PACKAGE(Sheets/views)' , 'BIM_SOFT_(Family Package)' , 'BIM_SOFT_GENERAL_PACKAGE_2' , 'BIM_SOFT_PACKAGE(Purge and Clean)' tab.

And then, refer screenshots and videos to run the application.

Screenshots

Commands

Installation/Uninstallation

The installer that ran when you downloaded this app/plug-in from Autodesk App Store will start installing the app/plug-in. OR, simply double-click the downloaded installer to install the app/plugin.

To uninstall this plug-in, exit the Autodesk product if you are currently running it, simply rerun the installer, and select the "Uninstall" button. OR, click Control Panel > Programs > Programs and Features (Windows 7/8.1/10) and uninstall as you would any other application from your system.

Additional Information

Known Issues

Define the needed shared parameter file for the tools from under below path.

C:\ProgramData\Autodesk\ApplicationPlugins\BIME_BIM_SOFT_SOLUTIONS_ALL_APPS.bundle\Contents\Documentation\Resources\SharedParameters.txt

Contact

Company Name: BIM SOFT SOLUTIONS
Support Contact: bim_s_s@yahoo.com

Author/Company Information

BIM SOFT SOLUTIONS

Support Information

Version History

Version Number Version Description

1.1.10

1. Updating "Distribute MEP elements automatically on ceiling" tool.

1.1.9

1. Updating "Distribute & Import MEP Elements from CAD" tool.

1.1.8

1. Updating "Copy Electrical Circuits" tool . 2. Updating "3D view from (section, callout, Scope Box) to work with section box" tool. 3.Updating "Batch Assign Scope Box to Views" tool . 4.Updating "Distribute & Import MEP Elements from CAD" tool.

1.1.7

1. Updating "Copy Electrical Circuits" tool to copy the load name when copying circuits. 2. Updating 3D view from (section, callout, Scope Box) to work with section box. 3.Updating Batch Assign Scope Box to Views.

1.1.6

1.Adding "Multi Connect Conduit and Fixtures" tool. 2.Adding "Convert pipe to conduit" tool. 3. Adding "Batch create 3d view from section or callout view" tool. 4. Adding "Batch convert floor plans and ceiling plans to 3D" tool. 5.Adding "Automatic creation for ceiling from rooms" tool. 6.Adding "Automatic Spot Coordinates" tool. 7.Updating Create electrical wire from lines tool "The created wire will be connected to the fixtures connector." 8.Updating "Create (Pipes, Ducts, Conduits and Trays) from CAD" tool to be able to select the level to place the created object. 9.Updating "Export NWC" tool.

1.1.5

Find and Replace Text in Parameters updated : The tool will work with all modeling categories , also the new update will include (sheets and views) categories.

1.1.4

1.Updating batch rename view tool. 2.Updating Create Cable tool by adding the ability to add 1 cable or sets of cables above the existing ones and manually define the vertical elevation for the new cable or cables. 3.Fixed bug in Super Hangers tool, which caused an error while working with fabrication elements. 4. Adding Multi connect Air Terminals to the MEP package.

1.1.3

1.Adding Auto. dimensions for MEP fixtures at ceiling tool to MEP package. 2.Adding Multi split pipes tool to MEP package. 3.Adding Multi Connect Fire Sprinklers to fire pipe to MEP package. 4.Adding Create spaces in all levels to MEP package. 5.Updating Distribute & Import MEP Elements from CAD tool (MEP package). a. Adding the ability to work with hosted families and place it at (Ceiling, Linked ceiling, Reference Plane) 6.Updating Distribute MEP elements automatically on ceiling tool (MEP package). a. Added ability to work with irregular spaces. b. Added ability to place element at linked ceiling 7.Update Automatic Conduit tool (MEP package). a. Adding option to create electrical circuit or not. b. The tool will alert the user if any of the selected elements not having conduit connector. 8.Update Super Hangers tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 9.Update Convert Wire Size (AWG to MM) tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 10.Update Batch change circuit breaker size tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 11.Update Automatic Circuit Breaker tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 12.Update Copy Electrical Circuits tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 13.Update Tag the second connector tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 14.Update Magic Dampers tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 15.Update Duct weight calculator using SMACNA catalogue tool (MEP package). a. The tool will alert the user in case, it failed to automatically define the needed shared parameters. 16.Update renumber tool (General Package). a. Adding prefix or suffix to the number 17.Adding create floors from lines tool (General Package). 18.Updating extract panel schedule (MEP package). a. Sorting panel names by panel names. 19. Adding Create rooms in all levels tool (General Package). 20. Updating license issue for (Edit sheet parameters, Copy Sheets, Batch (add/remove legend) tools

1.1.2

Adding Create (Pipes, Ducts, Conduits and Trays) from CAD tool https://apps.autodesk.com/RVT/en/Detail/Index?id=4693392944922706077&appLang=en&os=Win64

1.1.1

1.Updating"Align & coordinate Lighting with ceiling grids" tool. 2.Updating Magic Dampers tool, the tool will define shared parameters called " Exclude_Damper_Placement" under each duct you can check it to exclude any duct from placing damper on it. 3.Updating Automatic Circuit Breaker tool ,the tool will define shared parameter called "EXCLUDE" automatically, you can check it under any circuits to prevent breaker. rating change. 4.Updating Automatically offset elements on Ceiling. 5.Updating ,Duct weight calculator using SMACNA catalogue tool ,the tool will automatically define the needed shared parameters. 6.Updating Copy circuit tool usage instructions inside the tool user interface. 7.Updating Convert Wire Size (AWG to MM) tool. 8.Updating Create electrical wire from lines tool.

1.1.0

1.Update "family rename" tool. 2.Adding "purge file location" tool. 3.Adding "Align & coordinate Air terminals with ceiling grids" tool. 4.Adding "Align & coordinate Lighting with ceiling grids" tool.

1.0.0

First release.