LengthMEP
Win64, EnglishGeneral Usage Instructions
The add-in links the following shared parameters:
- layoutlength_length: Length type.
- layoutlength_string: String type.
- layoutlength_X: X coordinate of the element.
- layoutlength_Y: Y coordinate of the element.
- layoutlength_Z: Z coordinate of the element.
- layoutlength_R: Rotation of the element.
To the following categories will be attached the layoutlength_length and layoutlength_string parameters:
- Conduit.
- Wires.
- Duct.
- Flex Duct.
- Pipe.
- Flex Pipe.
- Cable Tray.
The XYZ coordinates and rotation data will be saved for the following categories:
Mechanical: Mechanical Equipment, Duct Terminal.
Electrical: Electrical Equipment, Lighting Devices, Lighting Fixtures, Electrical Fixtures, Nurse Call Devices, Telephone Devices, Fire Alarm Devices, Data Devices, Communication Devices, Security Devices.
Plumbing: Plumbing Fixtures and Sprinklers.
The add-in has four buttons:
1. LengthMEP:
Create the schedules of quantities of the categories (Conduits, Cable Tray, Pipes, Flex pipes, Duct, Flex Duct), and to update the total values per diameter or size.
2.Selection:
Shows the total length in the previous categories and wires drawed; the user must previously select the elements.
3.XYZ:
Shows the Finder window of the app to search elements with the folloeing filters:
·Conduit unconnected.
·Cable Trays unconnected.
·Pipes unconnected.
·Flexpipes unconnected.
·Ducts unconnected.
·Flexducts unconnected.
·Electrical XYZ and Rotation/Different.
·Plumbing XYZ and Rotation/Different.
·Mechanical XYZ and Rotation/Different.
The user can search in the model the unconnected elements or MEP elements with different location, that can change lengths of systems.
4.Circuit path:
Change the circuit path of all electrical circuits in the model to the option selected:
·All devices.
·Farthest device.
·Straight path (Custom, straight path from the panel to the farthest element).
Commands
Installation/Uninstallation
The installer that ran when you downloaded this app/plug-in from the Autodesk App Store will start installing the app/plug-in. OR, simply double-click the downloaded installer to install the app/plugin. You may need to restart the Autodesk product to activate the app/plug-in. To uninstall this plug-in, exit the Autodesk product if you are currently running it, simply rerun the installer, and select the "Uninstall" button. OR, click Control Panel > Programs > Programs and Features (Windows 10/11) and uninstall as you would any other application from your system.
Additional Information
Known Issues
Contact
Author/Company Information
Support Information
Contact: dqprojectsaddins@gmail.com
Version History
Version Number | Version Description |
---|---|
1.1.0 |
Schedule creation adapted to feet, fractional inches, or meters according to project units. Compatible with any Revit language version. Finder window to search MEP elements with unconnected endpoints. Save XYZ coordinates and rotation data to verify MEP elements. Change the circuit path of all electrical circuits based on selection. |
1.0.0 |
Initial release |