Circuit Number
Win64, EnglishGeneral Usage Instructions
To access the UI, navigate to Clicker panel and from Electrical Ribbon Panel click on "Circuit Number" and user interface will appear.
First must check this :
- Ensure the establishment of an Electrical Distribution System that is consistent for both the electrical panel, electrical fixtures and electrical fixtures.
- Verify that the inputted circuit number adheres to one of the following formats:
- Number
- Number + (Phase A Label Value or Phase B Label Value or Phase C Label Value) (e.g., 3R, 3Y, 3B, ...)
- (Phase A Label Value or Phase B Label Value or Phase C Label Value) + Number (e.g., R2, Y2, B2, ...)
- Ensure that the phasing format used in your project is consistent. Verify the phasing format by going to the Manage Panel, selecting the MEP Settings from the Ribbon Panel, and then clicking on Electrical Settings. From the list, choose General and check the values for Phase A, Phase B, and Phase C.
- Make certain that there are no duplicate electrical panels with the same name.
- Make sure circuit number not exceeded the maximum allowed for single-pole breakers in selected panel.
- Select the electrical panel from the provided list or from the active view using the button next to the electrical panel list (Combox).
- Choose the electrical fixtures or lighting fixtures from the active view or use the pick button to select fixtures.
- Check fixture and panel have same distibution system.
Once all these steps are verified, proceed with the following procedure:
- Select the panel.
- Choose lighting Fixtures or electrical fixtures.
- Input the circuit number.
- Click on the power button to execute the operation
Commands
Installation/Uninstallation
The installer that ran when you downloaded this app/plug-in from the Autodesk App Store will start installing the app/plug-in. OR, simply double-click the downloaded installer to install the app/plugin.
To uninstall this plug-in, exit the Autodesk product if you are currently running it, simply rerun the installer, and select the "Uninstall" button. OR, click Control Panel > Programs > Programs and Features (Windows 10/11) and uninstall as you would any other application from your system.
Additional Information
We plan to add additional functionality shortly. Please feel free to email your suggestions to mohamed.yasser2311@gamil.com
Known Issues
Circuit number necessitates read-and-write permissions to the user's local Windows roaming profile and the installation folder.
The application will encounter failure in the absence of read/write access.
The plugin will not function properly if the Electrical Distribution System differs between the electrical panel and electrical fixtures.
If buttons not work (Pick,Power) try to restart Autodesk® Revit®.
Entering circuit numbers in these formats 1, 1R, or R1 will trigger a message, but a circuit will be created at circuit number 1.
If a circuit number is entered, and the panel already has a circuit assigned to that number, the inputted circuit will be assigned to the first available empty circuit.
Attempting to input a circuit number that exceeds the maximum allowed for single-pole breakers in the selected panel will result in the creation of the circuit being unsuccessful.
Contact
Author/Company Information
Support Information
Email support is available through mohamed.yasser2311@gamil.com
Version History
Version Number | Version Description |
---|---|
2.0.0 |
Updated for Revit 2025 (.NET Core 8) Updated logo. Update phasing format to be compatible with any phasing format (e.g., RYB, ABC, or another format). Add a minimize button to the user interface. Fix power circuit when fixture have a connected with wire without electrical circuit. Fix phasing format to be compatible with both one-column and two-column panel schedules. |
1.0.0 |
First release. |